INFICON STC-2000A Thin Film Deposition Controller Operating Manual User Manual

Page 207

Advertising
background image

p

STC-2000A DEPOSITION CONTROLLER

y

[RZCD_ILDV] (H or I) if film #, parameter #, or new value is of improper value.
[RZCD_ILSN] if too many arguments, wrong delimiters, etc..

______________________________________________________________________
Film parameter access values:
______________________________________________________________________

Parameter 1

Density

access:

DENS

Value Range

0.40 - 99.99

Units

gm/cc

Reads Or Sets The Density Parameter depending which prefix letter A or B is used.
______________________________________________________________________

Parameter 2

Z Factor

access:

ZRAT

io

Value Range

0.100 - 9.999

Units None
Reads Or Sets The Z Factor Parameter depending which prefix letter A or B is used.
______________________________________________________________________

(Obsolete)

Parameter 3

Tooling Xtal 1

access:

OBSOLETE Was sensor 1 tool

Value Range

10.0 - 400.0

Units

Percent

______________________________________________________________________

(Obsolete)

Parameter 4

Tooling Xtal 2

access:

OBSOLETE Was sensor 2 tool

Value Range

10.0 - 400.0

Units

Percent

Reads or sets depending which prefix letter A or B is used, the tooling factor parameters.
These correspond to the two sensors available on the STC-2000A.
______________________________________________________________________

(Obsolete)

Parameter 5

Start Xtal #

access:

OBSOLETE Was initial channel

Value Range

0,1

Units

0 is Sensor 1, 1 is Sensor 2

This indicates which of the 2 sensor crystals will be used for a deposition run.
______________________________________________________________________

Parameter 6

Setpoint Thk Lim

access:

STHK

Setpoint Thickness Limit

Value Range

0.000 - 999.999

Units

Kilo

Angstroms

The setpoint thickness parameter is used to provide a comparison point for the STC-
2000A thickness setpoint event. This event will be triggered whenever the thickness
display equals or exceeds the setpoint value.
______________________________________________________________________


(non-sequencing

mode

only)

Parameter 7

Final Thickness Limit (Trigger)

access:

FTHK final thickness, end of run trigger

Value Range

0.000 - 999.999

Units

Kilo

Angstroms

SECTION 6.XX

page 207 of 292