INFICON STC-2000A Thin Film Deposition Controller Operating Manual User Manual

Page 83

Advertising
background image

p

STC-2000A DEPOSITION CONTROLLER

y

This parameter is used to associate a specific sensor map to a specific film. When a film becomes

active, it will invoke the map number named by this parameter. The map itself is edited/changed within the
REVIEW SS MAP menu.
____________________________________________________________________
Parameter

POCKET SELECT

Select Value; Range is 0 – 63

Units

Pockets

Pocket Select

This parameter is used to provide pocket information from a specific film in conjunction with the

ss map parameter: indexer sync mode. If indexer sync mode is set for either delay or feedback, then
following an XTAL verify, the indexer activity will commence before arriving at the RISE1 phase. Either a
1 of N or a binary (3 digit) value issued through output relays by I/O programming will select the correct
pocket. If indexer sync mode is set to none, then the POCKET SELECT parameter has no effect.
____________________________________________________________________
Parameter

ETCHING MODE

Polarity Value: OFF/ON

Units

None


Etching Mode

This parameter sets the STC-2000A for either a deposit mode (positive rate) when set to OFF or

an etch mode (negative rate) when set to ON.
____________________________________________________________________