Ip (increment position), Motion – Yaskawa SMC–4000 User Manual

Page 142

Advertising
background image

132

SMC–4000 User Manual

IP (Increment Position)

[Motion]

DESCRIPTION:

The IP command allows for an update in the commanded position while the motor is moving. This
command does not require a

BG (Begin)

command. The command has three effects depending on the

motion being executed. The units of this command are quadrature counts.

Case 1: Motor is standing still

An IP n command is equivalent to a

PR (Position Relative)

n and

BG (Begin)

command. The motor will

move to the specified position at the requested slew speed and acceleration.

Case 2: Motor is moving towards specified position

An IP n command will cause the motor to move to a new position target, which is the old target plus n. n
must be in the same direction as the existing motion (final target cannot be closer).

Case 3: Motor is in Jog Mode

An

IP (Increment Position)

n command will cause the motor to instantly try to servo to a position n from the

present instantaneous position. The

SP (Speed)

and

AC (Acceleration)

parameters have no effect. This

command is useful for making small corrections when synchronizing 2 axes in which one of the axis' speed
is indeterminate due to a variable diameter pulley.

Warning: When the motor is in jog mode, an

IP (Increment Position)

command will create an instantaneous position

error. In this mode, the IP should only be used to make small incremental position movements.

ARGUMENTS: IP x, y, z, w or IPX=x or IP a, b, c, d where

x, y z, w, or a, b, c, d are unsigned integers

USAGE:

EXAMPLES:

While Moving

Yes

Minimum Value

-2147483648

In a Program

Yes

Maximum Value

2147483647

Command Line

Yes

Default Value

n/a

Can be Interrogated

Yes

Default Format

10.0

Used as an Operand

No

Virtual Axis

No

:IP 50

50 counts with set acceleration and speed

#CORRECT

Label

AC 100000

Set acceleration

JG 10000;BG

Jog at 10000 counts/sec rate

WT 1000

Wait 1000 msec

IP 10

Move the motor 10 counts instantaneously

ST

Stop Motion