Of (offset), Tuning – Yaskawa SMC–4000 User Manual

Page 180

Advertising
background image

170

SMC–4000 User Manual

OF (Offset)

[Tuning]

DESCRIPTION:

The OF command sets a bias voltage in the motor command output or returns a previously set value. This
can be used to counteract gravity or an offset in an amplifier. If the PID values are zero, then the output
voltage will be the OF value.

This command is useful when compensating for gravity in a vertical load application.

ARGUMENTS: OF x, y, z, w or OFX=x or OF a, b, c, d where

x, y z, w, or a, b, c, d are signed integers

USAGE:

OPERAND USAGE:

_OFn contains the offset in volts where n is an axis letter.

EXAMPLES:

While Moving

Yes

Minimum Value

-9.9988

In a Program

Yes

Maximum Value

9.9988

Command Line

Yes

Default Value

0

Can be Interrogated

Yes

Default Format

1.4

Used as an Operand

Yes

OF 1

Set offset to 1 volt

OF ?

Return offset

1.0000

Advertising