Command summary - electronic gearing, Electronic gearing – Yaskawa SMC–4000 User Manual

Page 290

Advertising
background image

280

SMC–4000 User Manual

Electronic Gearing

This mode allows any axes to be electronically geared to some master axes. The masters may rotate in
both directions and the geared axis will follow at the specified gear ratio. The gear ratio may be different
for each axis and changed during motion.

The command

GA (Master Axis for Gearing)

ABCD specifies the master axes.

GR (Gear Ratio)

x,y

specifies the gear ratios for the slaves where the ratio may be a number between +/-127.9999 with a
fractional resolution of 0.0001. There are two modes: standard gearing and gantry mode. The gantry mode
is enabled with the command GM. GR 0,0 turns off gearing in both modes. A limit switch or

ST (Stop)

command disables gearing in the standard mode but not in the gantry mode.

The command

GM (Gantry Mode)

a,b,c,d selects the axis to be controlled under the gantry mode. The

parameter 1 enables gantry mode, and 0 disables it.

GR (Gear Ratio)

causes the specified axes to be geared to the actual position of the master. The master axis

is commanded with motion commands such as

PR (Position Relative)

,

PA (Position Absolute)

, or

JG

(Jog)

.

When the master axis is driven by the controller in the jog mode or an independent motion mode, it is
possible to define the master as the command position of that axis, rather than the actual position. The
designation of the commanded position master is the letter, C. For example, GACA indicates that the
gearing is the commanded position of A.

An alternative gearing method is to synchronize the slave motor to the commanded vector motion of
several axes performed by GAS. For example, if the A and B motor form a circular motion, the C axis may
move in proportion to the vector move. Similarly, if A, B and C perform a linear interpolation move, W
can be geared to the vector move.

Electronic gearing allows the geared motor to perform a second independent or coordinated move in
addition to the gearing. For example, when a geared motor follows a master at a ratio of 1:1, it may be
advanced an additional distance with

PR (Position Relative)

,

JG (Jog)

,

VP (Vector Position)

, or

LI (Linear

Interpolation Distance)

commands.

Command Summary - Electronic Gearing

Command

Description

GA n

Specifies master axes for gearing where n=A,B,C,D for main encoder as master.

n=CA,CB,CC,CD for commanded position.

n=DA,DB,DC,DD for auxiliary encoders.

n=S or T for gearing to coordinated motion.

GR a,b,c,d

Sets gear ratio for slave axes. 0 disables electronic gearing for specified axis.

GM a,b,c,d

1 sets gantry mode, 0 disables gantry mode.

MR a,b,c,d

Trippoint for reverse motion past specified value. Only one field may be used.

MF a,b,c,d

Trippoint for forward motion past specified value. Only one field may be used.