SMC–4000 User Manual
WC (Wait for Contour)
[Program Flow]
DESCRIPTION:
The WC command acts as a flag in the Contour Mode. After this command is executed, the controller does
not receive any new data until the internal contour data buffer is ready to accept new commands. This
command prevents the contour data from overwriting itself in the contour data buffer.
USAGE:
RELATED COMMANDS:
EXAMPLES:
While Moving
Yes
Default Value
---
In a Program
Yes
Default Format
---
Command Line
Yes
Can be Interrogated
No
Used as an Operand
No
CM
Specify contour mode
DT 4
Specify time increment for contour
CD 200
Specify incremental position
WC
Wait for contour data to complete
CD 100
WC
Wait for contour data to complete
DT 0
Stop contour
CD 0
Exit mode