Smc–4000 user manual – Yaskawa SMC–4000 User Manual

Page 261

Advertising
background image

251

SMC–4000 User Manual

SMC–4000 Command Interrogation List

Command

Definition

units

min

max

default

_AB

Status of abort input

status

0=Aborted

1=OK

n/a

_ACx

Axis acceleration rate

counts/sec2

1024

67107840

256000

_AEx

"Last absolute encoder read (0=X, 1=Y, etc)"

code

0

3

n/a

_ALx

High speed position capture status

status

0=TRIPPED

1=NOT YET

0

_AV

Distance from the start of vector sequence

counts

0

2147483647

0

_BGx

Is axis in motion?

status

0=NO

1=YES

0=NO

_BK

The program debug breakpoint

line number

-2000

2000

0

_BLx

Reverse software limit

counts

-2147483648

2147483647

-2147483648

_BN

Serial number of the SMC–4000

n/a

1

65535

n/a

_CEx

Type of encoder selected

configuration

0

15

0

_CF

Returns the default port that unsolicited messages are directed to

(ASCII)

configuration

65 = 'A'

83 = 'S'

83 = 'S'

_CM

Is the contour mode buffer full?

status

0=NO

1=YES

0=NO

_CN

Returns the configuration of the limit switches

configuration

-1 = Active Low 1 = Active High -1 = Active Low

_CN1

Returns the configuration of the home input

configuration

-1 = Active Low 1 = Active High -1 = Active Low

_CN2

Returns the configuration of the latch input

configuration

-1 = Active Low 1 = Active High -1 = Active Low

_CN3

Returns the configuration of the selective abort function

configuration

_CS

Current segment number for Vector Mode

segment

0

511

0

_CW

Port #1 data adjustment (MG from prog, chars have bit 8 set)

status

1=SET

2=OFF

2=OFF

_DA

Number of available arrays

quantity

0

30

30

_DCx

Axis deceleration rate

counts/sec2

1024

67107840

256000

_DEx

Encoder position of the auxiliary encoder

counts

-2147483648

2147483647

n/a

_DL

Number of available labels

quantity

0

510

510

_DM

Number of available array locations

quantity

0

2000

2000

_DPx

Current encoder position of axis

counts

-2147483648

2147483647

n/a

_DT

Time interval for contour mode

2N mSec

0

8

0

_DVx

Is the axis using dual loop PID?

status

0=NO

1=YES

0=NO

_EB

Is CAM mode enabled?

status

0=NO

1=YES

0=NO

_EC

returns the current index into the cam table

pointer

0

1024

0

_ED

The last line that caused a CMDERR

line number

0

999

n/a

_EGx

Is CAMMING axis engaged?

status

0=NO

1=YES

0=NO

_EMx

Cam cycle for camming (master or slave)

counts

0

2147483647

0

_EO

Is echo mode on?

status

0=NO

1=YES

0=NO

_EP

CAMMING interval (resolution)

counts

1

32767

256

_EQx

Status of ECAM slave

status

0

3

0

_ERx

Axis following error limit

counts

0

32767

16384

_ES

Ellipse scale ratio

n/a

0.0001

1

1

_FAx

Axis acceleration feedforward

constant

0

8191

0

_FLx

Forward software limit

counts

-2147483648

2147483647

2147483647

_FVx

Axis velocity feedforward

constant

0

8191

0

_GRx

Gear ratio of the axis

constant

-127.9999

127.9999

0

_HMx

State of the home switch

status

0=ACTIVE

1=INACTIVE

n/a

_HXx

Thread info (x is thread 0 through 3)

0=NOT

RUNNING

1=RUNNING

2=AT

TRIPPOINT

n/a

_IA

Returns the IP address as a 32 bit signed number

address

0

2147483647

0

_IA1

Returns the Ethernet retry time

mSec

0

2147483647

250

_IA2

Returns the number of available handles

handles

0

8

8

_IA3

Returns the number of the handle using this operand

handle

0

5

n/a

_IHh0

Returns the IP address as a 32 bit signed number ("h" is handle

"A" - "H")

address

-2147483648

2147483647

-1

Advertising