Mw (modbus wait), Configuration – Yaskawa SMC–4000 User Manual
Page 172

162
SMC–4000 User Manual
MW (Modbus Wait)
[Configuration]
DESCRIPTION:
The MW command sets the controller to wait for the ACK signal from a remote I/O device before going to
the next command. With this setting disabled, the controller will continue executing commands after an I/O
command that requires it to send a modbus packet. In this mode, the I/O state cannot be guaranteed.
Enabling this setting is the default, and is recommended. This is a configuration command and only needs to
be set once in the program. This configuration is not burnable, and is set to “enabled” at power up.
ARGUMENTS: MW n
where
n is 0 to disable the Modbus Wait function.
n is 1 to enable the Modbus Wait function.
USAGE:
OPERAND USAGE:
_MW contains the contains current setting of the MW command.
RELATED COMMANDS:
EXAMPLES:
Typically this command would be set once at the top of the application program.
While Moving
Yes
Minimum Value
0
In a Program
Yes
Maximum Value
1
Command Line
Yes
Default Value
0
Can be Interrogated
Yes
Used as an Operand
Yes
MW1
Enable Modbus Wait function.