Lc (lock controller), Configuration – Yaskawa SMC–4000 User Manual

Page 152

Advertising
background image

142

SMC–4000 User Manual

LC (Lock Controller)

[Configuration]

DESCRIPTION:

The (LC) Lock Controller command is used to prohibit the execution of certain commands from the serial
port by setting a security password. See the table below for a list of commands that are disabled in the
“Locked”mode. When this command is successfully executed, it automatically burns the new configuration
into the EEPROM. All parameters listedon the

BN (Burn Parameters)

page are stored when LC is

succesfully executed.

ARGUMENTS: LC p, l where

p is the password as previously established with the "PW" command.

"l" is the Lock setting, 0=Unlock,

USAGE:

OPERAND USAGE:

_LC will return the lock state of the controller, 0 = not locked, 1 = specific commands locked, 2 = All
commands locked including from serial port and ethernet port except the LC command.

RELATED COMMANDS:

PW (Password)

COMMANDS DISABLED WHILE LOCKED = 1:

EXAMPLES:

1

Lock commands (see table),

2

Lock commands and prohibit setting any commands from the serial port.

3

Allow download but lock PW, UL, TR, LS, and ED

While Moving

Yes

Default Value

---

In a Program

No

Default Format

---

Command Line

Yes

Used as an Operand

Yes

Can be Interrogated

Yes

BN (Burn Parameters)

TR (Trace Mode)

BP (Burn Program)

DL (Download)

BV (Burn Variables)

LS (List Program)

UL (Upload)

ED (Edit Mode)

IA (Internet Address)

PW (Password)

LC apple,2

Locks controller, assuming the valid password

is “apple.”

BN

Burn command (invalid when locked)

?

Receive question mark

TC1

Tell Code returns “Command not valid while

controller is locked.”