SMC–4000 User Manual

AC (Acceleration)

[Motion]

DESCRIPTION:

The Acceleration (AC) command sets the linear acceleration rate for independent moves, such as

PR

(Position Relative)

,

PA (Position Absolute)

and

JG (Jog)

moves. The parameters input will be rounded

down to the nearest factor of 1024. The units of the parameters are counts per second squared. The
acceleration rate may be changed during motion. The

DC (Deceleration)

command is used to specify the

deceleration rate.

ARGUMENTS: AC x, y, z, w or ACX=x or AC a, b, c, d where

x, y z, w, or a, b, c, d are unsigned integers

USAGE:

OPERAND USAGE:

_ACn contains the value of acceleration in counts/

sec

2

where n is an axis letter.

RELATED COMMANDS:

DC (Deceleration)

FA (Acceleration Feedforward)

IT (Independent Time Constant)

EXAMPLES:

HINTS: Specify realistic acceleration rates based on your physical system such as motor torque rating, loads, and amplifier

current rating. Specifying an excessive acceleration will cause large following error during acceleration and the
motor will not follow the commanded profile. The acceleration feedforward command FA will help minimize error
during acceleration.

While Moving

Yes

Minimum Value

1024

In a Program

Yes

Maximum Value

67107840

Command Line

Yes

Default Value

256000

Can be Interrogated

Yes

Default Format

8.0

Used as an Operand

Yes

Virtual Axis

Yes

AC 150000

Set acceleration to 150000 counts/sec

2

MG_ACX

Request the current acceleration setting

0149504

Returned Acceleration (resolution, 1024)

V=_ACX

Assigns the current acceleration setting to the

variable V