11 Troubleshooting

Overview

The following discussion may help you get your system running if a problem is encountered.

Potential problems have been divided into groups as follows:

1.

Installation

2.

Stability and Compensation

3.

Operation

The various symptoms along with the cause and the remedy are described in the following tables.

Installation

Stability

Symptom

Cause

Remedy

Motor runs away when connected to amplifier

with no additional inputs.

Amplifier offset

too large.

Adjust amplifier offset

Same as above, but offset adjustment does not

stop motor.

Damaged

amplifier.

Replace amplifier.

Controller does not read changes in encoder

position.

Wrong encoder

connections.

Check encoder wiring.

Same as above

Bad encoder

Check the encoder

signals. Replace encoder

if necessary.

Same as above

Bad controller

Connect the encoder to

different axis input. If it

works, controller failure.

Repair or replace.

Symptom

Cause

Remedy

Motor runs away when the

loop is closed.

Wrong feedback polarity.
(Positive Feedback)

Invert the polarity of the loop by

inverting the motor leads (brush

type) or the encoder (channel A+,

B+ if single ended; channel A+, A-

and B+, B- if differential)

Motor oscillates.

Too high gain or too little

damping.

Decrease KI and KP. Increase KD.