Lt (latch target), Motion – Yaskawa SMC–4000 User Manual

Page 161

Advertising
background image

151

SMC–4000 User Manual

LT (Latch Target)

[Motion]

DESCRIPTION:

The LT command is used for stopping an axis a defined distance after a registration mark (latch) input. The
distance specified by the LT command is in encoder counts. The distance must be sufficiently large for the
controller to decelerate normally at the specified deceleration rate. A stop code will be generated if the
distance is too small to stop for the deceleration rate or if the speed is too high. To Disable the latch target,
set LTX=0.

ARGUMENTS: LTX=x LTx,y,z,w LTa,b,c,d Where abcdxyzw are integers

POSSIBLE STOP CODES:

1 Motors stopped at commanded independent position (Latch input not received)

40 Stopped at Latch Target.

41 Latch Target overrun due to limit switch or stop command.

42 Latch Target overrun due to insufficient distance.

USAGE:

RELATED COMMANDS:

AL (Arm Latch)

RL (Report Latch)

EXAMPLES:

While Moving

Yes

Default Value

n/a

In a Program

Yes

Default Format

---

Command Line

Yes

Can be Interrogated

Yes

Used as an Operand

Yes

Virtual Axis

No

ALX

Set latch function

LTX=25000

Set Latch Target to stop 25000 counts
after registration

PRX=100000

Position Relative Move

BGX

Begin Motion

AMX

After Motion

JP #NOMRK,_SCX=1

Jump to #NOMARK routine if did not
receive a registration mark

Advertising