SMC–4000 User Manual

Command Summary - Coordinated Motion Sequence

Operand Summary - Coordinated Motion Sequence

When AV is used as an operand, _AV returns the distance traveled along the sequence.

The operands _VPX and _VPY can be used to return the coordinates of the last point specified along the
path.

Command

Description

VM m,n,p

Specifies the axes for planar motion where m and n represent the planar axes and p

is the tangent axis.

VP m,n

Return coordinate of last point, where m=X,Y,Z or W.

VS n

Specify vector speed or feedrate of sequence.

VA n

Specify vector acceleration along the sequence.

VD n

Specify vector deceleration along the sequence.

VR n

Specify vector speed ratio

BGS

Begin motion sequence

CS

Clear sequence.

AV n

Trippoint for After Relative Vector distance, n.

AMS

Holds execution of next command until Motion Sequence is complete.

TN m,n

Tangent scale and offset

ES m,n

Ellipse scale factor

VT

S curve smoothing constant for coordinated moves

Operand

Description

_vpm

The absolute coordinate of the axes at the last intersection along the sequence.

_AV

Distance traveled.

_LM

Number of available spaces for linear and circular segments in the SMC–4000

sequence buffer. Zero means buffer is full. 512 means buffer is empty.

_CS

Segment counter - Number of the segment in the sequence, starting at zero.

_VE

Vector length of coordinated move sequence.