Bp (burn program) – Yaskawa SMC–4000 User Manual
Page 81
Advertising
71
SMC–4000 User Manual
BP (Burn Program)
[General]
DESCRIPTION:
The BP command saves the application program and cam data in non-volatile EEPROM memory. This
command typically takes up to 10 seconds to execute and must not be interrupted. If the burn is disrupted
by power failure, a memory checksum error will result. The controller returns a <: >when the Burn is
complete.
ARGUMENTS: None
USAGE:
While Moving
No
Default Value
---
In a Program
No
Command Line
Yes
Can be Interrogated
No
Used as an Operand
No