Syntax

show poe config [port=

port

]

Parameter

port

Specifies a port. You can view more than one port at a

time. For instructions on how to enter port numbers,
refer to “Port Numbers in Commands” on page 47.

Description

Entering this command without specifying a port displays the following
PoE information:

ˆ

Maximum available power - The total amount of available power on the
switch for powered devices. This value is 380 W for the AT-9424T/
POE switch.

ˆ

Power threshold - The percentage of the maximum available power
which, if exceeded by the powered devices, causes the switch to send
an SNMP trap to your management workstation and enter an event in
the event log. At the default setting of 95%, the switch sends an SNMP
trap when the PoE devices require more than 361 W, which is 95% of
380 W, the maximum available power on the AT-9424T/POE switch.

Entering the command with the PORT parameter, displays this PoE
information about the specified port:

ˆ

PoE function - The status of PoE on a port, which can be either
enabled or disabled. The default is enabled.

ˆ

Power priority - The port’s priority, which can be critical, high, or low.
The default is low.

ˆ

Power limit - The maximum amount of power available to a powered
device. The default value is 15.4 W.

Examples

This command displays general PoE information:

show poe config

This command displays PoE information for port 4:

show poe config port=4