H3C Technologies H3C WX3000E Series Wireless Switches User Manual

Page 91

Advertising
background image

75

Figure 52 Network time

3.

Configure system time parameters as described in

Table 33

.

4.

Click Apply.

Table 33 Configuration items

Item Description

Clock status

Display the synchronization status of the system clock.

Local Reference Source

Set the IP address of the local clock source to 127.127.1.u, where u
ranges from 0 to 3, representing the NTP process ID.

If the IP address of the local clock source is specified, the local clock

is used as the reference clock, and thus can provide time for other
devices.

If the IP address of the local clock source is not specified, the local

clock is not used as the reference clock.

Stratum

Set the stratum level of the local clock.
The stratum level of the local clock decides the precision of the local

clock. A higher value indicates a lower precision. A stratum 1 clock has
the highest precision, and a stratum 16 clock is not synchronized and

cannot be used as a reference clock.

Source Interface

Set the source interface for an NTP message.
If you do not want the IP address of a certain interface on the local
device to become the destination address of response messages, you

can specify the source interface for NTP messages, so that the source IP
address in the NTP messages is the primary IP address of this interface.

If the specified source interface is down, the source IP address of the

NTP messages sent is the primary IP address of the outbound interface.

Advertising