HC08 ICS P&E Multilink/Cyclone Pro Connections

Connection Procedure

383

Microcontrollers Debugger Manual

3. The device power selection in the Power/Clock Details area allows the user to specify

whether the target is 2, 3, or 5 Volts, and whether this power is switched/generated by
the P&E interface or if it is separately supplied to the target and under user control. If it
is under user control, the software uses dialog boxes to prompt the user to power the
target up and down when necessary (similar to Class II-IV). See

Figure 15.3

.

Figure 15.3 Device Power Selection Box

Figure 15.4 M68HC08 Device Clock Selection Box

4. The device clock menu allows two options. See

Figure 15.4

.

• P&E provides clock to target

• The device has its own clock

5. Click on Refresh, which detects all P&E devices that are automatically detected, such

as Cyclone Pro USB, Cyclone Pro Ethernet and USB ML MON08 Multilink. See

Figure 15.2

.

6. To add a serial/parallel port P&E device such as Cyclone Pro Serial, MON08

Multilink and Cyclone Pro Ethernet (IP outside of subnet mask), proceed to Interface
Selection Manager by pressing the Add A Connection button. For more information
about configuring Cyclone Pro for ethernet operation, see the Cyclone Pro User's
Manual.

7. To remove a manually configured interface, click on Remove Connection button and

choose the interface to be deleted. See

Figure 15.5

.