Yokogawa DAQWORX User Manual

Page 172

Advertising
background image

6-17

IM WX101-01E

1

2

3

4

5

6

7

8

9

Index

Event Processor

10. Click the “Target File” tab to display the “Target File Page.”

11. Select “Data File” from the “File Type” list box.

12. Click the “Process” tab to display the “Process Page.”

13. Click a number in the “No.” column to select the process number.

14. Select “Convert” from the “Process” list box.

15. Select “Text” from the “Convert To” list box.

16. Select “Target File” from the “Input File” list box.

17. Select “Auto Name” or “Select File” from the “Output File” list box. If Auto Name is

selected, a text file is created using the name of the created data file with .txt extension.

18. Specify the range of tags or groups over which the process is executed through “Tag

Range” or “Group Range.”

These check boxes are valid when Input File is set to “Data File.”

Select the check box and specify “Start” and “End.”

Pressing the button to the right of “Start” or “End” displays the Group Selection

dialog box or Tag Selection dialog box.

Click the desired group or tag. The dialog box closes and the selected group or

tag is applied.

19. Click “OK” to save the settings. For details on saving events, see section 6.2.

6.1 Setting Events

Advertising
This manual is related to the following products: