Basic setting operation – Yokogawa DAQWORX User Manual

Page 182

Advertising
background image

7-6

IM WX101-01E

Basic Setting Operation

The operations in tab panels are summarized as the following two types.

Recorder-to-recorder copy and channel-to-channel copy are convenient editor functions.

Operation in Channel tab panels

• Operations in the tab panels for channel settings, which are titled with “Channel,”

“Meas,” or “Math.” However, the title may differ between each series.

• It is possible to input data directly to the items displayed in the tab panel, however,

dedicated entry dialog boxes are offered for efficient data input. You can open the
dedicated entry dialog box by double-clicking the “CH (channel)” cell.

Operation in tab panels other than Channel tab panels

• Operation in the tab panels titled with “Misc.,” “SETUP,” “Setting,” or “Setup.” However,

the title may differ between each series.

• For some panels, select an item from the listing displayed in the left part of the tab

panel and the corresponding settings items will be shown in the right. Input the

settings.

Recorder-to-recorder copy

You can copy the settings between recorders by using the “Copy” button in the “Recorder

List” window.

Note

• For VR, µR, and DARWIN, copying is only allowed on the same model. Copying is not

allowed if the /N1, /N3, and /N5 option codes differ, even if the model is the same. However,

if the calculation or IC memory options differ, copying is allowed. If the number of channels

differs, only the common channels are copied (VR, µR, DARWIN).

• For DX, MV, and CX, each system information item is copied.

Procedure

1. Click the “No.” cell of the source recorder, then press the “Copy” button.

The “Copy” dialog box appears.

2. Among the recorder model names shown in the “Copy” dialog box, select the

recorder to copy to (you can select more than one recorder). Then click “OK.”

7.3 Editing the Setting Parameters

Advertising
This manual is related to the following products: