Index

Setting the Recorder

“Display” command differs from recorder models as follows.

VR200 S2

µR1000/µR1800

DX100/MV100/CX1000

DX200/DX200C/MV200/CX2000

DR130/DR200

DC100

With “Display” command, note the following.

Note

• With models other than VR206 and VR106, sending any non-standard display will cause an

error.

• When manual display is selected with the µR series, you can select channels which do

not exist in the connected recorder. However, selecting nonexisting channels and sending

commands will cause a communication error.

• As for DR and DC, no communication error results, even if the display command that is not

applicable to the connected recorder is sent.

• With CX series instruments, if you enter settings related to program operation in “Mode” on

models with the /PG1 or /PG2 option prior to transmission, an error will occur.

• Batch recording can only be started if the Batch function is included on the instrument to

which the command is sent, and the Batch function is enabled.

Commands are sent as follows according to the batch setting.

Batch Setting

Sent Commands

Multibatch

All batch recording commands can be sent

Batch ON

ALL, and batch group 1 batch recording commands can be sent

Batch OFF

Batch recording commands cannot be sent (error)

7.16 Transmitting Control Commands to the Recorder