Monitor server

Set the port number and system number of the monitor server only when multiple

software applications are installed in the target PC and multiple monitor servers are

running. If you perform recorder model determination without specifying the port number

or the system number, the system with the smallest system number is searched.

Note

• If you are connecting to DAQEXPLORER or Gate, multiple system numbers are available

on a single monitor server.

• If you are connecting to Gate and you wish to acquire data from all systems, you can select “All

System No.” in the system number list box.

3. Select the “No.” column. Then, press the “Recorder Model Determination” button or

select “Recorder Model Determination” from the “Communication” menu.

The “Recorder Model Determination” button is enabled when you select “No” boxes
of recorders whose “Port” and “Address” have been entered.

If you perform recorder model determination, the software applications (displayed in
the “Model” cell) or the number of measurement channels on the target recorders is
identified. The monitor server must be running and scanning (data acquisition) must
be in progress on the software application for this to work.

Note

Note the following points depending on which software application you access.

• For communications with a PC running DAQLOGGER

Before acquiring data, start the DAQLOGGER scan on the PC you will connect to.

On DAQLOGGER R5.01 or later, if you stop the scan during data acquisition, the connection

will be cut. On DAQLOGGER R3.0x or R4.0x, the data after the scan or calculation is

stopped will not be updated, and will remain at the same value. If you restart the scan, the

connection will be cut (however if auto connect is enabled in the logger condition settings,

the connection will be automatically reopened).

• For communications with a PC running DAQ32Plus

Before acquiring data, start the DAQ32Plus monitor on the PC you will connect to. If you

are running DAQ32Plus version R10.03 or later, you can not open a connection unless

the monitor is running. In addition, if you stop the monitor during data acquisition, the

connection will be cut. On DAQ32Plus R9.0x, R10.01, or R10.02, the data after the scan is

stopped will not be updated and will remain at the same value.

• For communications with a PC running DAQEXPLORER

Before acquiring data, turn monitoring ON on the DAQEXPLORER desktop at the PC you

will connect to, and mount the DAQSTATION or MobileCorder.

During data acquisition, if you turn the monitoring setting OFF on the mounted

DAQSTATION or MobileCorder or unmount it, the connection will be cut.

• For communications with a PC running MXLOGGER

Before acquiring data using DAQLOGGER, start the MXLOGGER scan (data acquisition) on

the PC you will connect to.

• For communications with a PC running a Gate application

For applications other than GateMX100 and GateMX/MW, execute the Gate process or

execute the service on the PC you will connect to, before acquiring data. If you stop the

gate process or service during data acquisition, the connection will be cut.

For GateMX100 and GateMX/MW, start data acquisition on the GateMX100 and GateMX/

MW before acquiring data. If you stop data acquisition on the GateMX100 and GateMX/MW

during data acquisition, the connection will be cut.