Yokogawa DAQWORX User Manual

Page 86

Advertising
background image

3-8

IM WX101-01E

5. Set the ON/OFF of the waveform display.

To display waveform in the graph, click the check box in the “No.” cell to turn it ON

(blue).

6. Set Y-axis display conditions.

Specify the ON/OFF of the Y-axis display when a multiple-axis zone is selected.

Also specify the scale of Y-axis (linear or logarithmic).

7. Select the type of meter display in the “Meter Type” cell from bar meter, analog

meter, and thermometer.

Note

The meter type setting is valid only for the meter monitor.

8. Click the value in the “Scale” cell and type the scale value.

The selectable range is from -1016 to 1016 disregarding the decimal point.

If you set the minimum value to a larger value than the maximum value, the
waveform will be displayed flipped from top to bottom.

Note

The decimal point positions of the entered values are adjusted for each tag according to the

number of significant digits to the right of the decimal point.

9. Click the value in the “Zone” cell and type the value that specifies the display zone.

The selectable range for minimum and maximum values are from 0 to 99% and from

1 to 100%, respectively.

On the monitor window, waveforms are displayed in zones where the top and bottom

of the waveform display area of the trend monitor correspond to 100% and 0%,

respectively.

10. Click the values in the “Trip 1” and “Trip 2” cells and type the display positions for trip

points 1 and 2.

Click the check box to specify the Use (blue)/ Not Use of the trip point.

3.2 Setting the Display Conditions