Action

The action to be executed when an event occurs.

Settings

Description

Memory Start/Stop

-

Memory Start

-

Memory Stop

-

Trigger

*2

Can be specified when the DX is configured to record event data.

AlarmACK

Cannot be specified when the event is set to [Relay], [Switch], or
[Alarm].

Math Start/Stop

Can be specified on /M1 and /PM1 options.

MathStart

Can be specified on /M1 and /PM1 options.

MathStop

Can be specified on /M1 and /PM1 options.

Math Reset

Can be specified on /M1 and /PM1 options.

Save Display Data

Can be specified when the DX is configured to record display data.

Save Event Data

Can be specified when the DX is configured to record event data.

Message

Set the message number and the destination. Set the message
destination to all groups (All) or a group number.

Snapshot

-

Display Update Interval
Change

Can be specified when the function for switching between the trend
update interval and the secondary update interval is enabled.

Manual Sample

-

Timer Reset

Cannot be specified when the event is set to [Timer].

Display Group Change

Specify the number of the group to be displayed.

Flag

Can be specified on /M1 and /PM1 options.

Time ADJUST

Can be specified only when the event is set to [Remote].

Panel Load

*2

Can be specified only when the event is set to [Remote].

Alarm Display Reset

*1

You can specify this when the annunciator sequence is set to use
the “ISA-M” annunciator and the event is set to [Remote], [User
Key], or [Edge].

Comment Display

*1

Specify the comment text block number to display.

Favorite Display

*1

Choose which registered display to switch to.

Set [Action] to [Key] or [Select].

Settings

Description

Key

Performs the same operation as pressing the favorite
key.

Select

Displays the specified favorite screen. Set the
registration numbers of the screens you want to specify
in the [No.] boxes.

*1 Available in release numbers 3 and later.
*2 Cannot be selected on DXs with the /AS1 advanced security option.

When the multi batch function (/BT2 option; release number 3 or later) is enabled,

specify the target batch group when you set the action to any of the settings below.

Settings that require the
designation of a specific batch
group

Memory Start/Stop
Memory Start
Memory Stop
Math Reset
Save Display Data
Save Event Data
Message
Display Group Change