Error Messages and Their Corrective

Actions

Software Configurator

Warning

Code

Warning message

What to do

W3331

The µR1000 and µR1800 cannot be distinguished

automatically. Please select the correct recorder model.

Select µR1800 or µR1000 manually.

W3332

The recorder model can’t be recognized. It will be

regarded as not connected.

Check the model of the connected recorder.

W3333

The VR100 and VR200 cannot be distinguished

automatically. Please select the correct recorder model.

Select VR100 or VR200 manually.

Message

Code

Message

What to do

M3361

Model determination was successful.

— — — —

Hardware Configurator

Code

Error message

What to do

E3401

Failed to send command. Settings don’t fit currently
connected model or computations may be in progress.

Check the model of the connected recorder. If
computation processing is in progress, stop the
computation then send command.

E3402

Failed to receive command. Settings don’t fit currently

connected model.

Check the model of the connected recorder.

E3403

File is invalid. Hardware Configuration settings will
return to default.

Check if you have specified a hardware
configuration setting file.

E3404

Cannot send command while IC memory is in use.

Stop the IC memory operation, then send command.

E3405

Data memory is full. Please delete all data and send
again.

Clear the data memory, then send data.

E3408

Invalid user name or password.

Use the Software Configurator to check the user
name and password.

E3409

Data cannot be send when logged in as User. Login as
administrator and send again.

Use the Software Configurator to set the login name
of administrator.

E3410

Some setting could not be sent.

Check the model and options of the connected
recorder.

E3411

Cannot send command while computations or memory
sampling are in progress.

Stop the recorder’s memory sampling or computation
processing, then send command.

E3412

This file does not fit settings made with DAQLOGGER
Software Configurator. Cannot read this file.

Abort loading. Check the contents of the file.

E3413

Communication not possible. Temperature units don't
match.

Check the temperature unit.

E3414

Connected to different model.

Check the connected device.

E3415

Please change connected hardware to SET mode.

Check the connected device.

E3416

Please enter an equation.

Set an expression.

E3417

Unknown symbol is entered. Please change equation.

Check the setup parameters.

E3418

Invalid channel number is entered. Please change
equation.

Check the setup parameters.

E3419

Incorrect use of parenthesis. Please change equation.

Check the setup parameters.

E3420

Grammatical error. Please change equation.

Check the setup parameters.

E3421

These data were generated by another model.

Check the setup parameters.

E3422

Temperature units in file must match software.

Check the temperature unit.

E3423

Failed to load data. Some data initialized.

Check the contents of the file.

E3424

Invalid channels are included in the copy source.

Check the copy source and copy destination
settings.

E3425

Character string is incorrect.

Check the setup parameters.

E3426

Invalid channel number.

Check the channel number.

E3427

For input range, please keep CH numbers Left < Right.

Check the setup parameters.

E3428

Channel number is already being used!

Check the setup parameters.

E3429

Incorrect file name!

Check the file name and extension.

E3430

Now Controlling. Can’t store settings.

Send the settings after halting control operations on
the CX.