Setting the Recorder

• Start channel/End channel (master channel numbers)

Enter the first and last channel numbers of input/output. The range of channels that

you can enter varies depending on the command type as follows:

Read: 201 to 440, R-Math: C01 to C60, Write: 1 to 48, W-Math: 101 to 160

Exchange-M (release numbers 4 and later): C01 to C60

• Address

Enter the address of the slave device in the range of 1 to 247.

• Register

Set the register number of the server.

For an input register, select in the range of 30001 to 39999 and 300001 to 365536.

For a hold register, select in the range of 40001 to 49999 and 400001 to 465536.

The register numbers you can specify vary depending on the command type. See

section 6.3 in the DX1000/DX1000N/DX2000 Communication Interface User’s

Manual.

• Type

Select INT16, UINT16, INT32_B, INT32_L, UINT32_B, UINT32_L, FLOAT_B, or

FLOAT_L.

The type you can specify vary depending on the command type. See section

6.3 in the DX1000/DX1000N/DX2000 Communication Interface User’s Manual

(IM04L41B01-17E).

In release number 3, FLOAT has been added as a data type for measurement channel

data and computation channel data.