7.5
Setting µR Series
Changing any of the system configurations, will result in initialization of Hardware
Configurator settings. Therefore, perform system configuration before making any other
settings.
Editing the Settings
Below are the settings windows for µR1000 and µR1800. The items which cannot be set
are displayed in gray and you cannot input to them.
For details of each setting item, see the manual of the recorder.
The display examples in the following are those for µR1800.
“Channel” tab panel
Double-clicking the “CH” cell in this panel opens the “Channel Setting” dialog box (see
page 7-18) for input.
You can input from either the panel or the dialog box.
Enter the constant
to be used in the
expression
Enter the scale
Pressing this bar closes/opens
the “Constant” dialog box
Double clicking here
shows the “Channel
Setting” dialog box
Set the span
Turn ON/OFF the square
root computation
Turn ON/OFF the scaling
Select the range type
Select the input mode
Enter the alarm value
Select the alarm type
Select the relay number
Select the reference for
the difference computation
Enter the display zone
Turn ON/OFF the partial expanded display
Turn ON/OFF digital printing
Enter the tag name Enter the unit Enter the expression
Turn ON/OFF saving data to IC memory card
• Mode
Input type. Select “MATH” for a computation channel.