Configuring the DAQLOGGER

• Entering the settings manually

A. If necessary, click the “Model” cell and select the model name from the list box.

On the other hand, after selecting an area of the “Model” cells, clicking the tool cell
in the bottom will copy the selected area’s first cell model to all other cells in the
selected area.

B. If necessary, click the “Meas Ch.” cell and select the correct measurement channel

from the list box.

The number of channels displayed in the list box varies depending on the model.

• VR100:

1, 2, 3, 4, or 6

• VR200 and VR200 S2: 1, 2, 3, 4, or 6

• µR1000:

1, 2, 3, 4, or 6

• µR1800:

1, 2, 3, 4, 6, 12, 18, or 24

• DX100, DX1000:

2, 4, 6, or 12

• DX200:

4, 8, 10, 20, or 30

• DX200C:

4 or 8

• DX2000:

4, 8, 10, 20, 30, or 48

• MV100:

2, 4, 6, or 12

• MV200:

4, 8, 10, 20, or 30

• CX1000:

NONE, 6

• CX2000:

NONE, 10, or 20

• MV1000:

NONE, 4, 6, 8, 12, 24

• MV2000:

NONE, 8,10, 20, 30, 40, 48

• DARWIN:

Not selectable, see “Setting DARWIN options and the
subunit/module configuration”

Note

For a description of the settings for DAQEXPLORER, DAQ32Plus, DAQLOGGER,
MXLOGGER, and Gate, see “Setting the Environment When Communicating with a PC with
Software Applications Installed” (page 2-22).

C. If necessary, click the “Math Ch.” cell and select the correct computation channel

from the list box.

The number of channels displayed in the list box varies depending on the model.

• VR100:

Not selectable (no computation option)

• VR200 or VR200 S2 : NONE, 1, 2, 3, 4, 6

• µR1000:

NONE, 4 (when the num of meas. channels is 1, 2, 3, or 4)

NONE, 6 (when the num of meas. channels is 6)

• µR1800:

NONE, 4 (when the num of meas. channels is 1, 2, 3, or 4)

None, 12 (when the num of meas. channels is 6, 12, 18, or 24)

• DX100:

NONE, 4, or 8 (when the num of meas. channels is 2 or 4)

None, 12 (when the num of meas. channels is 6 or 12)

• DX200:

None, 8 (when the num of meas. channels is 4 or 8)

None, 30 (when the num of meas. channels is 10, 20, or 30)

• DX200C:

None, 8

• DX1000:

NONE, 12 (when the num of meas. channels is 2 or 4), 24
(when the num of meas. channels is 6 or 12)

• DX2000:

NONE, 12 (when the num of meas. channels is 4 or 8), 60
(when the num of meas. channels is 10, 20, 30, 40, or 48)

• MV100:

NONE, 4, or 8 (when the num of meas. channels is 2 or 4)

None, 12 (when the num of meas. channels is 6 or 12)

• MV200:

None, 8 (when the num of meas. channels is 4 or 8)

None, 30 (when the num of meas. channels is 10, 20, or 30)

• MV1000:

NONE, 12 (when the num of meas. channels is 4 or 8), 24
(when the num of meas. channels is 12 or 24)

• MV2000:

NONE, 12 (when the num of meas. channels is 8), 60 (when
the num of meas. channels is 10, 20, 30, 40, or 48)

• CX1000:

None, 12

• CX2000:

None, 30

• DARWIN:

None, 30 (“standalone” models)

None, 60 (“expandable” models)

• Monitor Server Type: Not available, since there are no computation channels.