4-12 Wiring with Pico GFX-70

The options for setting output and marker relays are listed with the description
of each coil function.

The function block coil functions and parameters are listed with the
description of each function block type.

Markers, Analog Operands

Specific markers are available for actively addressing values or inputs/outputs.

When using the COM communication mode, you can make the following data
accesses on the slave. Note the REMOTE MARKER SETTING in the
following table.

Table 4.4 Markers

Markers

Analog operand

Pico GFX-70
display

Number

Value
range

Access type

r = Read
w = Write

Marker 32-bit

MD

01

96

32-bit

r, w

Marker 16-bit

MW

01

96

16-bit

r, w

Marker 8-bit

MB

01

96

8-bit

r, w

Marker 1-bit

M

0

96

1-bit

r, w

Analog inputs basic
unit

IA X

X=01

04

10-bit

r

Analog output

QA X

X=01

10-bit

r, w

Advertising