Rockwell Automation 1760-xxxx Pico GFX-70 Controllers User Manual User Manual
Page 250

Publication 1760-UM002B-EN-P - March 2005
4-140 Wiring with Pico GFX-70
The parameter display for a timing relay is used to modify the switching
function, time base or setpoint times and enable the parameter display.
T 02 X
M:S +
>I1
>I2
QV>
Table 4.63 Parameter display and parameter set for timing relay
T 02
Timing relay function block number 02
X
On-delayed mode
M:S
Time range Minute: Seconds
+
Appears in the parameter display
>I1
Time setpoint value 1
>I2
Time setpoint value I2 (on a timing relay with 2 setpoint values)
QV>
Timed-out actual time in RUN mode
Table 4.64 Timing Relay Modes
Parameter
Switch function
X
On-delayed switching
?X
On-delayed with random time range
❚
Off-delayed switching
?
❚
Off-delayed with random time range
X
❚
On and off delayed
Off-delayed with random time range, setpoint retriggerable
?
Off-delayed with random time range, retriggerable
?X
❚
On and off delayed switching with random time, 2 time setpoints
Single-pulse switching
Switch with flashing, synchronous, 2 time setpoint values
Switch with flashing, asynchronous, 2 time setpoint values