Visualization with Pico GFX-70 5-33

Screen 6 - Screen 6 is basically the same as screen 5 except that Inverted was
selected for the Display change function. When input I2 = 1 (make contact bit
logic), the message text in this screen can thus be inverted.

Figure 5.37 Message text inverted

Screen 7 - Screen 7 is basically the same as screen 6 except that the inverted
display is controlled by timing relay T07 (asynchronous clock pulse). The text
flashes in the display at different pulse and pause times.

Figure 5.38 Message text inverted flashing

Message Text Example Program 2 – Activating Message Texts with a Timing Relay

The program consists of two screens containing message texts. The screens
are activated automatically in succession in the display. The circuit diagram
uses six on-delayed timing relays T01 to T06 that activate outputs Q1 to Q4
and LE03 in succession after an elapsed time. This operation is run in a
continuous loop since timing relay T06 resets all timing relays after a set time.

The screen activation is executed via counter C01. This has the value 1 as the
upper setpoint SH. The counter values 0 and 1 are therefore used as activation
values for the two screens. The resetting of timing relays T01 to T06 by T06
activates counter C01 which then reaches the value 1 and therefore has already
reached its upper setpoint. This then causes screen 2 to be displayed. The
on-delayed timing relay T08 resets counter C01 back to 0 after the set time (0.8
s) has elapsed. Screen 1 is then displayed again and timing relay T08 is no
longer activated. This loop is repeated continuously.

Standard path

: C:\Program Files\PicoSoft 6 Pro\samples\

Program:

Message text_manual screen change.e60

Screen 1 - The first screen contains four message text elements. These are
activated in succession via the outputs Q1 to Q4 and appear in the display.

Screen 2 - The second screen contains one message text element with one
message text.

I2 not actuated

I2 actuated

invert

via I2!

Q2 ON

invert

via I2!

Q2 OFF

flashing

via timer

Q2 ON

flashing

via timer

Q2 ON

Start Machine 1

Start Machine 2

Start Machine 3

Start Machine 4

RESTART