Wiring with Pico GFX-70 4-59
After a rising edge from 0 to 1 at coil BT01T_ the value 757935405 is present
in the marker double words MD80 and MD81.
Example:
Transfer of marker byte, range violation error.
The value of marker byte MB96 is to be transferred to MD93, MD94, MD95
and MD96. The length is 16 bytes.
Parameters of BT01 function block:
Source range:
>I1 MD96
Destination range:
>I2 MD93
Number of bytes:
>NO 18
Comparison
range 1
Value of marker
range 1
(decimal/binary)
Comparison range 2
Value of marker range 2 (decimal/binary)
MB60
45/
00101101
MD80 (Byte 1, LSB)
757935405/ 00101101001011010010110100101101
MD80 (Byte 2)
757935405/ 00101101001011010010110100101101
MD80 (Byte 3)
757935405/ 00101101001011010010110100101101
MD80 (Byte 4, MSB)
757935405/ 00101101001011010010110100101101
MD81 (Byte 1, LSB)
757935405/ 00101101001011010010110100101101
MD81 (Byte 2)
757935405/ 00101101001011010010110100101101
MD81 (Byte 3)
757935405/ 00101100010110110010110100101101
MD81 (Byte 4, MSB)
757935405/ 00101101001011010010110100101101