4-124 Wiring with Pico GFX-70
In the parameter display of a numerical converter you can change the mode
and the enable of the parameter display.
Numerical Converter Modes
Number Range
NC02
Numerical converter function block number 02
BCD
Convert BCD code to decimal value mode
+
Appears in the parameter display
>I1
Input value
QV>
Output value
Parameter
Mode
BCD
Convert BCD coded values to decimal values
BIN
Convert decimal value to BCD coded values
Value
Number system
-161061273 to +161061273
BCD
-9999999 to +9999999
Decimal
Advertising