Publication 1760-UM002B-EN-P - March 2005
6-18 Pico-Link and Point-to-Point Serial Connections
The normal rules for addressing the markers apply.
Configuration of the Serial Interface
The active station must have the following settings in order for the Serial
Interface connection to be functional:
• Baud rate,
• Serial Interface (active),
• Remote marker range (data exchange range).
Active station
Remote station
1 MD01
MD01
1 MW01
1MW02
MW01
MW02
1 MB01
1MB02
1MB03
1MB04
MB01
MB02
MB03
MB04
1 M01 to 1 M32
M01 to M32
1 MD02
MD02
1 MW03
1MW04
MW03
MW04
1 MB05
1 MB06
1 MB07
1 MB08
MB05
MB06
MB07
MB08
1 M33 to 1 M64
M33 to M64
1 MD03
MD03
1 MW05
1 MW06
MW05
MW06
1 MB09
1 MB10
1 MB11
1 MB12
MB09
MB10
MB11
MB12
1 M65 to 1 M96
M65 to M96
1 MD04
MD04
1 MW07
1 MW08
MW07
MW08
.....
....
....
1 MD20
MD20
1 MW39
1 MW40
MW39
MW40
1 MB77
1 MB78
1 MB79
1 MB80
MB77
MB78
MB79
MB80
IMPORTANT
Ensure a clear separation of the write range of the
two stations. The active station should write different
markers to the remote station. Otherwise the markers
in the last write operation will be overwritten.