Connecting the power supply, Connecting the power supply -17 – Rockwell Automation 1760-xxxx Pico GFX-70 Controllers User Manual User Manual

Page 51

Advertising
background image

Publication 1760-UM002B-EN-P - March 2005

Installation 2-17

Connecting the Power
Supply

1760-IA12XOW6I Expansion Units

Figure 2.17 Power supply on the AC expansion units

TIP

The required connection data for both device types GFX,
1760-IB12XOB8 with 24V dc and 1760-IA12XOW6I with
standard voltages of 100V ac to 240V ac are shown on page
A-1.

The Pico GFX-70 devices run a system test for one second
after the power supply has been switched on. Either RUN
or STOP mode will be activated after this time depending
on the default setting.

ATTENTION

A short current surge will be produced when switching on
for the first time. Do not switch on the module via Reed
contacts since these may burn or melt.

N

N

L

N

F1

L

100-240 V

~

E+ E-

R1

...

R12