Publication 1760-UM002B-EN-P - March 2005

4-48 Wiring with Pico GFX-70

• Constants
• Markers MD, MW, MB
• Analog inputs IA01 to IA04

IA01: terminal I7

IA02: terminal I8

IA03: terminal I11

IA04: terminal I12

• Analog output QA01
• Actual value

QV> of another function block

Specifying the marker range without offset

If MB, MW or MD markers are specified at both

>I1

and

>I2

the number of

the markers is the start of comparison range 1 or 2.

Specifying the marker range with offset

If you wish to work with an offset, specify one of the following variables at
function block input

>I1

or

>I2

:

• Constant,
• Actual value ..QV of a function block,
• Analog input IA..,
• Analog output QA..

The value at the input is taken as the offset to marker MB01.

Displaying the Parameter Set in the PARAMETERS Menu

• + Access enabled
• -: Access disabled

Contacts

BC01E1 to BC32E1: the number of comparison elements exceeds one of the
comparison ranges.

BC01E2 to BC32E2: the two comparison ranges overlap.

BC01E3 to BC32E3: the specified offset of the comparison ranges is outside
of the permissible range.