Rockwell Automation 1760-xxxx Pico GFX-70 Controllers User Manual User Manual
Page 323
![background image](/manuals/579694/323/background.png)
Publication 1760-UM002B-EN-P - March 2005
Pico-Link and Point-to-Point Serial Connections 6-17
Establishing a Serial Interface connection to a Pico-Link station.
Figure 6.6 Pico-Link operation and Serial Interface connections.
A Serial Interface connection can be established with a Pico-Link station. The
same conditions apply here as with operation without Pico-Link.
Data accesses via Serial Interface
The following data access operations are possible from the active station to the
remote station:
Write/read accesses in the marker range
Active station, read
Remote station
Inputs
1I01 to 1I16
I01 to I16
Inputs of local expansion unit
1R1 to 1R16
R01 to R16
Outputs
1Q01 to 1Q08
Q01 to Q08
Outputs of local expansion unit
1S01 to 1S08
S01 to S08
Pico-Link diagnostics bits
1ID01 to 1ID08
ID01 to ID08
Analog inputs
1IA01 to 1IA04
IA01 to IA04
Analog output
1QA01
QA01
GFX-70
GFX-70
GFX-70
GFX-70