Setting Up Trending

12-3

To set the trigger condition:

1.

2.

3.

If you want variable X to be a:

Then:

Parameter value

Identify the parameter number of that parameter.

Constant value

Select a desired constant value in the range of +32767
to -32768.

If you have identified a parameter
number for variable X and are
programming Trend:

Then enter the number of the parameter to be
sampled in:

1

P294

2

P306

3

P318

4

P330

If you have selected a constant
value for variable X and are
programming Trend

Then:

1

1. Set P294 to"0".
2. Enter the desired constant value
in P295.

2

1. Set P306 to"0".
2. Enter the desired constant value
in P307.

3

1. Set P318 to"0".
2. Enter the desired constant value
in P319.

4

1. Set P330 to"0".
2. Enter the desired constant value
in P331.