Appendix d, Programming parameters, Appendix – Rockwell Automation 2364F Regenerative DC Bus Supply Unit (RGU) User Manual

Page 145

Advertising
background image

Publication 2364F-5.01– October 2003

Appendix

D

Programming Parameters

This appendix lists the programming parameters for the RGU.

32

Host Command Word
[Host Command]

This parameter commands the processor to
perform the function(s) indicated by each fault bit
which is set to 1.

For example, to command the processor to clear

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0000 0000 0000 0000

Minimum Value

0000 0000 0000 0000

Maximum Value

0000 1111 1111 1111

Related Parameters

P33, P34, P35

faults, you would enter the command word, 0000
0000 0000 0001.

Bit

Description

0

Clr Faults

Sends a command to clear faults in the RGU

1

Enable Cmd

Sends a command to Enable RGU control

2

Meter Reset

Sends a command to reset the watt-hour meter

3

Save Command

Sends a command to save parameters

4

Param Recall

Sends a command to reset parameters

5

Default Init

Sends a command to initialize parameters to their defaults

6

Clr Warnings

Sends a command to clear warnings in the RGU

7

Reset Cmd

Sends a command to reset the RGU

8

Clr Flt Que

Sends a command to clear the fault queue

9

Clr Wrn Que

Sends a command to clear the warning queue

10

Disable Cmd

Sends a command to Disable the RGU control

11

Run Startup

Sends a command to reset the RGU and to initiate the startup sequence

12-15

Not Used

Bit

8

Bit

9

Bit
10

Bit
11

Bit
12

Bit
13

Bit
14

Bit
15

Bit

0

Bit

1

Bit

2

Bit

3

Bit

4

Bit

5

Bit

6

Bit

7

A

Parameter Number

B

Parameter Name

C

Screen Text
This indicates the name shown on the display.

D

Parameter Description
This describes the parameter’s function and its relationship with other
parameters. This may include diagrams and programming examples.

E

Bit Number
For parameters displayed as words, the bits are displayed on the screen
from 15 to 0. Each bit can be set separately (if read/write parameter).

F

Bit Name
This indicates the bit name shown on the display screen.

G

Bit Description
This describes the function of the bit end may show its relationship
with other parameters or conditions.

H

Parameter Specifications
These fields indicate parameter attributes.

Parameter Type

Indicates whether the parameter is a source or
sink, and whether it is read/write or read only.
Indicates the units shown on the display (i.e. %,
Volts, uH).
Indicates the conversion formula for internal units.
For example, if the drive units are equal to
‘Display Units x 5120/100’, a value of 15 on the
display would be stored as 768 (15 x 5120/100)
internally.
Indicates the default value for this parameter.
Indicates the minimum value allowed.
Indicates the maximum value allowed.
Lists other parameters that are related in some

Display Units

Drive Units

Factory Default

way to this parameter.

Minimum Value
Maximum Value
Related Parameters

A

B

C

D

E

F

G

H

Advertising