Programming Parameters

247

SCANport Remote Data Out: P3
[Rem Data Out:P3]

This parameter shows the value that is being
passed out SCANport 3 (expansion port).

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0.00

Minimum Value

0.00

Maximum Value

65535

Related Parameters

P224, P225

248

SCANport Remote Data Out: P4
[Rem Data Out:P4]

This parameter shows the value that is being
passed out SCANport 4 (expansion port).

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0.00

Minimum Value

0.00

Maximum Value

65535

Related Parameters

P224, P225

249

SCANport Remote Data Out: P5
[Rem Data Out:P5]

This parameter shows the value that is being
passed out SCANport 5 (expansion port).

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0.00

Minimum Value

0.00

Maximum Value

65535

Related Parameters

P224, P225

250

SCANport Remote Data Out: P6
[Rem Data Out:P6]

This parameter shows the value that is being
passed out SCANport 6 (J7).

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0.00

Minimum Value

0.00

Maximum Value

65535

Related Parameters

P224, P225

251

SCANport Remote Data In: A1
[Rem Data In:A1]

This parameter shows the value of datalink A1
which is being received from a SCANport device.
This value may be used by linking other
parameters to this parameter.

Parameter Type

Source (Read Only)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0.00

Minimum Value

0.00

Maximum Value

65535

Related Parameters

P259

252

SCANport Remote Data In: A2
[Rem Data In:A2]

This parameter shows the value of datalink A2
which is being received from a SCANport device.
This value may be used by linking other
parameters to this parameter.

Parameter Type

Source (Read Only)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0.00

Minimum Value

0.00

Maximum Value

65535

Related Parameters

P251, P259

Using SCA Nport Rem ote Data In

A 1 D ata O ut

A 2 D ata O ut

B1 Data O ut

B2 Data O ut

C2 Data O ut

D 1 D ata O u t

C1 Data O ut

D 2 D ata O u t

P251 (D ata In A1)

P252 (D ata In A2)

P253 (D ata In B1)

P254 (D ata In B2)

P256 (D ata In C2)

P257 (D ata In D 1)

P255 (D ata In C1)

P258 (D ata In D 2)

RG U

S CA Nport Device

S CA N p ort D evice

RG U

00101011101100

A 1 Data O ut

Pxxx

Destination

Param eter 1

(Link to P251)

P 251

SCA Nport

R em ote

Data In: A 1

D atalink A 1