Rockwell Automation 2364F Regenerative DC Bus Supply Unit (RGU) User Manual

Page 179

Advertising
background image

Publication 2364F-5.01– October 2003

Programming Parameters

D-35

175

Fault Status 1 Report Mask
[Flt Report Mask 1]

This parameter selects the faults that can be
reported to P174.

1 - Report

0 - Suppress

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

1111 1111 1111 1111

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

Related Parameters

P174, P176

Bit

Description

Bit

Description

0*

ROM Bad CRC Reports ROM errors.

8*

R2R HW Error

Reports errors in the RGU-to-RGU hardware.

1*

RAM Error

Reports RAM errors.

9

Control Volt

Reports control voltage faults.

2*

BatRAM Err

Reports errors in the battery-backed RAM.

10*

H/S Overtemp

Reports when the heatsink is at overtemperature.

3*

DSP Load

Reports DSP loading faults.

11

Bus Low

Reports when the DC bus falls below min voltage.

4*

FPGA Load

Reports FPGA loading faults.

12

Bus High

Reports when the DC bus rises above max voltage.

5

Iq Foldback

Reports Iq foldback faults.

13

BRAM Chksum

Reports parity errors in the battery-backed RAM.

6*

M1 Open

Reports when the M1 contactor opens.

14*

Prchrg Fail

Reports when the precharge operation fails.

7

SCANport Err

Reports SCANport errors.

15*

DSP Timeout

Reports when the DSP times out.

* These items cannot be changed to zero.

176

Fault/Warning Select Mask 1
[Fault/Warn Mask1]

This parameter determines whether conditions
should be reported as a warning (0) or handled as
a fault (1).

The factory default, for example, shows that a

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

1100 0101 0101 1111

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

Related Parameters

P174, P176

heatsink overtemperature causes a fault
(bit 10 = 1) and a low bus voltage produces a
warning (bit 11 = 0).

Bit

Description

Bit

Description

0*

ROM Bad CRC Selects response to ROM error.

8*

R2R HW Error

Selects response to RGU-to-RGU hardware error.

1*

RAM Error

Selects response to RAM error.

9

Control Volt

Selects response to a control voltage condition.

2*

BatRAM Err

Selects response battery-backed RAM error.

10*

H/S Overtemp

Selects response to heatsink overtemperature.

3*

DSP Load

Selects response to DSP loading condition.

11

Bus Low

Selects response to low bus voltage (P28).

4*

FPGA Load

Selects response to an FPGA loading condition.

12

Bus High

Selects response to high bus voltage (P29).

5

Iq Foldback

Selects response to an Iq foldback error.

13

BRAM Chksum

Selects response to parity error in BRAM.

6*

M1 Open

Selects response to the M1 contactor opening.

14*

Prchrg Fail

Selects response to precharge failure.

7

SCANport Err

Selects response to SCANport errors.

15*

DSP Timeout

Selects response to a DSP timeout.

* These items cannot be changed to zero.

Bit

8

Bit

9

Bit
10

Bit
11

Bit
12

Bit
13

Bit
14

Bit
15

Bit

0

Bit

1

Bit

2

Bit

3

Bit

4

Bit

5

Bit

6

Bit

7

Bit

8

Bit

9

Bit
10

Bit
11

Bit
12

Bit
13

Bit
14

Bit
15

Bit

0

Bit

1

Bit

2

Bit

3

Bit

4

Bit

5

Bit

6

Bit

7

Advertising