Rockwell Automation 2364F Regenerative DC Bus Supply Unit (RGU) User Manual

Page 196

Advertising
background image

Publication 2364F-5.01– October 2003

D-52

Programming Parameters

272

RGU-to-RGU Transmit Indirect 2
[R2R Xmit Ind 2]

This parameter directs the master status indicated
in P20 (Master Status) to the R2R network.

Parameter Type

Source (Read Only)

Display Units

Parameter Number

Drive Units

Display Units * 1

Factory Default

20 (Master Status)

Minimum Value

1

Maximum Value

Maximum Defined Parameter Number

Related Parameters

P5, P20, P267

273

RGU-to-RGU Receive 1, Indirect 1
[R2R Rcv1, Ind1]

This parameter directs the Iq Current Reference
(P96) from the master to P89 (Auxiliary Iq Current
Command).

Parameter Type

Source (Read Only)

Display Units

Parameter Number

Drive Units

Display Units * 1

Factory Default

89 (Auxiliary Iq Current Command)

Minimum Value

1

Maximum Value

Maximum Defined Parameter Number

Related Parameters

P5, P89, P268

274

RGU-to-RGU Receive 1, Indirect 2
[R2R Rcv1, Ind2]

This parameter receives the status from the
master RGU through the R2R network. This
master status (Enabled/Faulted) is directed to P20
(Master Status).

Parameter Type

Source (Read Only)

Display Units

Parameter Number

Drive Units

Display Units * 1

Factory Default

20 (Master Status)

Minimum Value

1

Maximum Value

Maximum Defined Parameter Number

Related Parameters

P5, P20, P268

275-280

P275-P280 are for internal use only.

281

Scratch Pad 1
[Scratch Pad 1]

This parameter can be used to store
miscellaneous positive values.

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0

Minimum Value

0

Maximum Value

65535

282

Scratch Pad 2
[Scratch Pad 2]

This parameter can be used to store
miscellaneous positive values.

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0

Minimum Value

0

Maximum Value

65535

Master RGU

Slave RGU

P89

Auxiliary Iq

Current

Reference

P273

R2R

Receive 1,

Indirect 1

P271

R2R

Transmit

Indirect 1

P96

Iq

Reference

Master RGU

Slave RGU

P20

Master

Status

P274

R2R

Receive 1,

Indirect 2

P272

R2R

Transmit

Indirect 2

P20

Master

Status

Advertising