Publication 2364F-5.01– October 2003

D-64

Programming Parameters

342-401

P342-P401 are for internal use only.

402

Signal Processor 1 Input
[SigProc 1 Input]

This parameter indicates the parameter that is to
be processed through Signal Processor 1.

To process a value, set P402 to the parameter to
be processed, set P403 to the destination (where
you want the results), set P405 to the

Parameter Type

Sink (Read/Write)

Display Units

Parameter Number

Drive Units

Display Units * 1

Factory Default

0 (no selection)

Minimum Value

0

Maximum Value

Maximum Defined Parameter Number

Related Parameters

P403 to P406

offset value that should be applied to the source,
set P404 to the gain that should be applied to
the source value, and set P406 to the cutoff
frequency.

403

Signal Processor 1 Output
[SigProc 1 Output]

This parameter specifies where the results of the
processed value should be placed.

Parameter Type

Source (Read Only)

Display Units

Parameter Number

Drive Units

Display Units * 1

Factory Default

0

Minimum Value

0

Maximum Value

Maximum Defined Parameter Number

Related Parameters

P402 to P406

404

Signal Processor 1 Gain
[SigProc 1 Gain]

This parameter specifies the gain that should be
applied to the source value (indicated in P402).

Note that the offset is applied before the gain.

Parameter Type

Source (Read Only)

Display Units

None

Drive Units

Display Units * 1

Factory Default

1.00

Minimum Value

-4.00

Maximum Value

4.00

Related Parameters

P402 to P406

405

Signal Processor 1 Offset
[SigProc 1 Offset]

This parameter specifies the offset to apply to the
source value (indicated in P402).

Note that the offset is applied before the gain.

Parameter Type

Source (Read Only)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0

Minimum Value

-32768

Maximum Value

32767

Related Parameters

P402 to P406

406

Signal Processor 1 Cutoff Frequency
[SigProc 1 Cutoff]

This parameter specifies the cutoff frequency to
be used by the signal processor.

Parameter Type

Source (Read Only)

Display Units

R/S (rad/sec)

Drive Units

Display Units * 1

Factory Default

0

Minimum Value

-32768

Maximum Value

32767

Related Parameters

P402 to P405

P40 2

Signal

Processor 1

Input

P 405

Signal

Processor 1

O ffset

P404

Signal

Processor 1

G ain

P40 6

Signal

Processor 1

Cutoff Freq

P 403

Signal

Processor 1

O utput

+ /- adjustm ent to

source value

m ultiplier to

source value

adjusts the

frequency

specifies

destination

param eter

indicates source

param eter

Psss

S ource

Param eter

Pddd

D estination

P aram eter