Publication 2364F-5.01– October 2003

D-62

Programming Parameters

331

Trend 4 X Value
[Trend X Value]

This parameter defines a constant to be masked
with the trend Y value (P332 or P333).

To use this parameter, the trend X indirect (P330)
must equal zero.

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0

Minimum Value

-32768

Maximum Value

32767

Related Parameters

P329 to 340 (See also P298)

332

Trend 4 Operand Indirect Y
[Trend Y Ind]

This parameter designates a source parameter to
be analyzed in the Trend 3 evaluation. The
source value masks the trend X value (P330 or
P331). P333 (Trend 4 Y Value) is used as the
trend Y operand when this parameter equals zero.

Parameter Type

Sink (Read/Write)

Display Units

Parameter Number

Drive Units

Display Units * 1

Factory Default

0 (disabled, P333 enabled)

Minimum Value

0

Maximum Value

Maximum Defined Parameter Number

Related Parameters

P329 to 340 (See also P298)

333

Trend 4 Y Value
[Trend Y Value]

This parameter defines a constant used to mask
the trend X operand (P330 or P331).

To use this parameter, the trend Y indirect (P332)
must equal zero.

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0

Minimum Value

-32768

Maximum Value

32767

Related Parameters

P329 to 340 (See also P298)

334

Trend 4 Operator
[Trend Operator]

This parameter selects the operation to be
performed between trend X (P330 or P331) and
trend Y (P332 or P333). If trending is enabled
(P338), a true result of the operation will cause
the Trend 4 Input parameter value (from P329) to
be passed to the prescribed output (P340).

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

0 (GT)

Minimum Value

0

Maximum Value

7

Related Parameters

P329 to 340 (See also P298)

P298 (Trend 1 Operator) shows a sample
diagram of the trending configuration.

Value Description

Value Description

0

GTSelects the operation [Trend X must be greater than Trend Y].

4

ANDSelects the operation [Trend X AND Trend Y].

1

LTSelects the operation [Trend X must be less than Trend Y].

5

NANDSelects the operation [Trend X NAND Trend Y].

2

EQSelects the operation [Trend X must be equal to Trend Y].

6

ORSelects the operation [Trend X OR Trend Y].

3

NESelects the operation [Trend X must not be equal to Trend Y].

7

NORSelects the operation [Trend X NOR Trend Y].

335

Trend 4 Sample Rate
[Trend Samp Rate]

This parameter determines the rate of sampling
for Trend 4.

The value of this parameter can be changed in
increments of 0.002 sec.

Parameter Type

Sink (Read/Write)

Display Units

sec

Drive Units

Display Units * 2000

Factory Default

0.000

Minimum Value

0.000

Maximum Value

30.000

Related Parameters

P329 to 340 (See also P298)

336

Trend 4 Post Samples
[Trend Post Samp]

This parameter defines the number of samples
(out of 500) to be allocated for post-trigger
sampling.

Pre-samples + Post samples = 500 (0 to 499)

Parameter Type

Sink (Read/Write)

Display Units

None

Drive Units

Display Units * 1

Factory Default

10

Minimum Value

0

Maximum Value

499

Related Parameters

P329 to 340 (See also P298)