Appendix c, Physical specifications, Approximate shipping weights – Rockwell Automation 2364F Regenerative DC Bus Supply Unit (RGU) User Manual

Page 139: Physical details, Appendix

Advertising
background image

Publication 2364F-5.01– October 2003

Appendix

C

Physical Details

Physical Specifications

Table C.1 RGU Physical Specifications

The L, M, and N-code RGU heights include a 1.5 inch-high base channel (standard). This

base channel is an option for the J and K-code RGUs.

The M and N-code RGUs use both 20-inch deep MCC(s) and a 25-inch deep MCC, having

an overall depth of 25 inches. Figure 1 shows top-view illustrations of the M and N-code
RGUs.

The M-code height (103.5") includes the enclosure height (90"), the base channel (1.5"),

and a top hat assembly (12"). The top hat assembly is shipped loose from the unit.

Approximate Shipping Weights

Table C.2 Approximate Shipping Weights

The regenerative module for the J current code RGU is panel mounted. The regenerative

modules for the K, L, M, and N current code RGUs are built as roll-out module assemblies.

Current

Code

Height

"

Overall Width

Overall Depth

!

Number of MCC

Sections

J

90" (2286 mm)

25" (635 mm)

15 or 20" (508 mm)

1

K

90" (2286 mm)

45" (1143 mm)

20" (508 mm)

2

L

91.5" (2324 mm)

55" (1397 mm)

20" (508 mm)

2

M

103.5" (2629 mm)

#

70" (1778 mm)

25" (635 mm)

2

N

91.5" (2324 mm)

90" (2286 mm)

25" (635 mm)

3

Unit Current Code

Weight of Regenerative Module

"

Weight of Complete RGU Unit

J

85 lb (39 kg)

970 lb (440 kg)

K

260 lb (119 kg)

1450 lb (658 kg)

L

440 lb (200 kg)

2020 lb (916 kg)

M

1000 lb (455 kg)

2900 lb (1316 kg)

N

1000 lb (455 kg)

3850 lb (1746 kg)

Advertising