Setting the sampling rate, Setting the sampling rate -6 – Rockwell Automation 2364F Regenerative DC Bus Supply Unit (RGU) User Manual
Page 124
Advertising
Publication 2364F-5.01– October 2003
12-6
Setting Up Trending
Setting the Sampling Rate
You can specify how often you want the RGU to take data samples.
Data samples may be taken 2 milliseconds apart to 30 seconds apart.
Note: The trigger condition is evaluated:
•
at the rate of sampling whenever the sampling rate is less than 20
milliseconds
•
at 20 milliseconds whenever the sampling rate exceeds 20
milliseconds.
1. Select a sampling rate between 0 and 30 seconds.
2.
Note: The RGU will round the desired sample rate to the nearest
2-millisecond interval.
If you are programming Trend:
Then enter the sample rate in:
1
P299
2
P311
3
P323
4
P335
Advertising