Reading the status messages, See figure – AltiGen MAXCS 7.0 Update 1 ACM Administration User Manual

Page 131

Advertising
background image

Configuring the Triton T1/E1 Board

MaxCS 7.5 Administration Manual 115

Figure 64.

Triton E1 configuration dialog box

Reading the Status Messages

If the channel group is working, the Status line displays OK. This status line is updated every 3 seconds. If
there is an error, a message is displayed. The following table lists the types of error messages and the
appropriate actions.

Error Message

Meaning

Action

HW failure: <No Answer>

Major hardware problem. Board is
not responding to commands.
Reasons could be: 1) DSP
loading failure; 2) If PRI, board
failed.

1.

Reset board.

2.

If error continues, replace board.

HW failure: <No Clocks>

No clock signal is detected on T1
interface drop.

1.

Check MVIP clock.

2.

Reset board. If this does not work,
replace board.

L1 failure: <No Signal
(LOS)>

Layer 1 failure, physical layer;
LOS = Loss of Analog Signal

Check T1/PRI cable and change if
necessary. If cable is okay, CO is not
sending any signal. Contact CO.

L1 failure: <Alarm Indication
Signal (AIS)>

Layer 1 failure, CO sends all 1’s to
our T1/E1; AIS = Alarm Indicator
Signal; all ones detected

To locate the AIS alarm, have the
carrier check the T1 network element
connected to the T1 interface and trace
the problem.

L1 failure: <Remote Alarm
Indication (RAI)>

Layer 1 failure, CO notifies that
the configuration is wrong; RAI =
Remote Alarm Indicator

Correct the settings.

L1 failure: <No Sync Frames

Layer 1 failure, physical layer; no
valid framing is detected.

Possible span mis-configuration (ESF
is selected but the actual framing is SF,
or vice versa). Check span
configuration.