E1 pri, Configuring an isdn numbering plan – AltiGen MAXCS 7.0 Update 1 ACM Administration User Manual

Page 137

Advertising
background image

Configuring the Triton T1/E1 Board

MaxCS 7.5 Administration Manual 121

E1 PRI

Figure 70.

E1 PRI Switch Mode

The top three settings are used for a connection to a CO switch:

Austel TS014 PRI

ETSI NET5PRI

NT DMS-100 PRI

The bottom three settings are used for a PRI tie trunk configuration where two MAXCS systems are connected
back to back. In such a configuration, one MAXCS system must be configured as Network and the other as
User. For example, set one to NT DMS-100 PRI Network and the other to NT DMS-100 PRI.

Austel TS014 PRI Network

ETSI NET5PRI Network

NT DMS-100 PRI Network

Configuring an ISDN Numbering Plan

The ISDN Numbering Plan button in the Protocol Configuration window opens the PRI ISDN Numbering
Plan

dialog box. This function allows you to select how the system will identify and code the Called Number

for six different types of calls. This coding instructs the CO on how to interpret the number being sent to it.