Chapter 27: System Report Management

346

MaxCS 7.5 Administration Manual

Configure traps:

Memory usage exceeds

– This trap is sent when MAXCS detects that the lowest virtual memory usage

exceeds a specified percentage of physical memory configuration within a 10-minute duration. Default val-
ue is 80%. The next trap will be sent after the condition is cleared then occurs again. The minimum dura-
tion between any two consecutive traps is 30 minutes

Average CPU utilization exceeds

– This trap is sent when MAXCS detects its average CPU utilization

exceeds a specified percentage in any 10-minute duration. Default value is 80%. The next trap will be sent
after the condition is cleared then occurs again. The minimum duration between any two consecutive traps
is 30 minutes

Hard disk usage exceeds

– This trap is sent when hard disk usage of MAXCS transitioning from below

threshold to on or above threshold is detected. Default value is 80%. The minimum duration between any
two consecutive traps is 30 minutes.

List of Traps Sent

A trap is sent when the following conditions are detected.

Cold Start (generic trap). When AltiServ is cold started and initialized successfully.

Warm Start (generic trap). When AltiKeep service detects AltiServ.exe is down, re-starting AltiServ.exe,
and AltiServ is initialized successfully.

LinkDown (generic trap). When detecting a T1/E1/PRI span state is transitioning from up to down or losing
clock source.

When a gateway is down, one trap is sent for each T1/E1/PRI interface in this Gateway. This trap is sent
when SIP trunk destination state transitioning from reachable to unreachable is detected.

Every T1/E1/PRI span and SIP trunk channel is assigned a unique "ifIndex" value as a port identifier

LinkUp (generic trap). When a T1/E1/PRI span state transitioning from down to up is detected.