MaxCS 7.5 Administration Manual 397

A

P P E N D I X

A

E1-R2 and E1 ISDN PRI Installations

This section describes the configuration procedures necessary to implement E1 R2 digital signaling for
European, Pacific Rim, and other emerging markets. Please carefully follow the procedures step by step.
1.

Change the Configure Type to E1:

a.

From Boards view, double-click the board to be configured to open the Board Configuration
window.

b.

In the Board Configuration window, click the Board Configuration button.

c.

In the next Board Configuration window, select E1 as the configure type, and click OK.

Important:

When changing from E1 to T1, then back to E1, trunk channel properties and channel group
properties will be reset to default values. It is important to make sure the trunk channel properties
are configured properly. Continue to follow the steps below to re-check your settings for the
physical layer, data link layer and signaling layer.

2.

In the Board Configuration window, double-click the channel group.