Appendix A: E1-R2 and E1 ISDN PRI Installations

400

MaxCS 7.5 Administration Manual

Signaling Values, By Country

Table 1.

Signaling values, by country

Country

Signaling Values

Chile/Nacional MFC-R2

Set calling part category

: 1

[Assume no caller ID provided]:

Incoming sequence

: DID/DNIS

In-call signaling

(depend on how many DID digits):

For 3-digit DID, set to (113)6
For 4-digit DID, set to (1113)6
For 5-digit DID, set to (11113)6
For 6-digit DID, set to (111113)6
For 7-digit DID, set to (1111113)6
For 8-digit DID, set to (11111113)6
[Assume caller ID provided]:

Incoming sequence

(same as above shown): DID/DNIS * Caller ID

In-call signaling

(depend on how many DID digits):

For 3-digit DID, set to (115)*(K)36
For 4-digit DID, set to (1115)*(K)36
For 5-digit DID, set to (11115)*(K)36
For 6-digit DID, set to (111115)*(K)36
For 7-digit DID, set to (1111115)*(K)36
For 8-digit DID, set to (11111115)*(K)36

China MFC-R2

Set calling part category

: 3

[Assume no caller ID provided]:

Incoming sequence

: DID/DNIS

In-call signaling

(depend on how many DID digits):

For 3-digit DID, set to (113)1
For 4-digit DID, set to (1113)1
For 5-digit DID, set to (11113)1
For 6-digit DID, set to (111113)1
For 7-digit DID, set to (1111113)1
For 8-digit DID, set to (11111113)1
[Assume caller ID provided]:

Incoming sequence

(same as above shown):

DID/DNIS * Caller ID

In-call signaling

(depend on how many DID digits):

For 3-digit DID, set to (116)*(K)31
For 4-digit DID, set to (1116)*(K)31
For 5-digit DID, set to (11116)*(K)31
For 6-digit DID, set to (111116)*(K)31
For 7-digit DID, set to (1111116)*(K)31
For 8-digit DID, set to (11111116)*(K)31